GCP 1000

Aliphatic Polyurethane Top Coat

Zero VOC - Permanent - Multi Purpose - Water Based


Product Description:

GCP 1000 is a permanent two part, water- based, zero VOC, aliphatic polyurethane coating designed for anti-graffiti and multi- purpose general maintenance applications. A Green Leader in both performance and safety.

** Use the Gold Remover for graffiti removal.

Features & Benefits:

  • Zero VOC
  • Graffiti Resistant
  • Solvent Free, Odorless
  • Weather Resistant
  • Durable and Flexible
  • Chemical Resistant
  • LEED Qualified for EQ Credit 4.2
  • Approved in MPI categories 105 and 205 for anti-graffiti coatings
  • SCAQMD Super Compliant VOC Paint List
  • FDA, USDA, Green Compliant
  • Field tested/approved by City of Los Angeles
  • Excellent Color and Gloss Retention
  • Impact and Abrasion Resistant

Intended Uses:

  • Schools, Universities
  • Hospitals, Assisted Living
  • Commercial, Retail
  • Municipalities
  • Hospitality
  • Pharmaceutical
  • Automotive, Processing, Manufacturing
  • Concrete, Wood, Masonry, Metal, Structural Steel, Aluminum, Interior/Exterior Painted and Unpainted Surfaces

Characteristics:

Color/Finish: Clear satin or gloss. Custom colors available upon request. Custom colors may vary from batch to batch - manufacturer makes no guarantee as to exactness. Tinted material is only available in gloss finish.

(*) Clear Satin is recommended for surfaces where graffiti such as markers, ink, etc. are prevalent.

Reduction: Must be reduced with clean water. Slowly add 16-22 oz per 1 Unit Kit to reach desired viscosity.

Mil Thickness: 3-5 mils wet.

Application Method: Roll or Spray - airless or conventional. (*) GCP 1000 cannot be sprayed in Florida - it must be rolled or brushed.

Curing Mechanism: Evaporation/Infra-Red/ Conventional Oven.

Limitations:

  • GCP 1000 is a non-immersible coating.
  • GCP 1000 should not be applied in rain, high humidity or wind. Proper methods to protect over- spraying should be implemented.
  • Heavier applications can result in ambering, microblistering, poor adhesion and inconsistent sheen.
  • GCP 1000 applied to horizontal surfaces will become slippery when wet.
  • Slight discoloring may occur when clear is applied to lighter colors.
  • GCP 1000 is not a water repellent or sealer. Retaining or barrier surfaces for earth or flower beds or other such surfaces where moisture vapor transmission is a concern should first be properly sealed and waterproofed. A moisture and pH test must be conducted prior to application of product.
  • Efflorescence can cause product failure in certain bricks if they are not properly cured or conditioned prior to applying GCP 1000.
  • Clear satin should be tested prior to applying to wood.
  • Product should be compliant with all local, state and federal regulations when applied to previously coated surfaces.

Packaging:

All kits are pre-measured and shortfilled by weight. Kits yield the published coverage rates but may vary depending on application method and porosity of surface. Testing will establish coverage rates:

Kit Size Activator Base Case Qty
Sm Repair 1/2 pint tin Pint tin 6
Lg Repair Pint tin Quart tin 5
1 Unit Quart tin Gallon Pail 3
4 Unit Gallon tin 5 gal pail n/a

Storage:

Store up to 12 months, unopened at 45°F to 75°F. The material will withstand storage temperatures up to 90°F, but avoid prolonged exposure to sunlight and heat. KEEP FROM FREEZING.

Coverage Rates:

Spread rate is dependent on application method, substrate and anticipated level of use. The below figures are estimates. Testing should be completed for accurate figures. Application loss factor is not covered due to surface profile, porosity, surface irregularities, application technique, spillage, film build or climatic conditions. Coverage rates below are per 1 Unit Kit (4 Unit Kit will yield 4 times the coverage):

Surface SqFt Coats
Concrete 300 1 - 2
Brick 275 2
Wood 300 2
Metal, Steel 450 1 - 2
Tile 475 1

Technical Data:

Resin Type: Aliphatic Polyurethane

% Solids by Weight / Volume: Mixed:

Clear - 60% (+/- 2%) / 58%

Tinted - 66% (+/- 2%) / 64%

Pot Life: 1.5 to 2 hours

Dry Time: ASTM D1640
Temperature and Humidity Dependent:

50°F & 80% RH @ 3 mils wet:

To touch:   6 hours

Tack Free & Re-Coat:   8 hours

Dry Hard:   24 hours

75°F & 50% RH @ 3 mils wet:

To touch:   4 hours

Tack Free & Re-Coat:   6 hours

Dry Hard:   24 hours

Full Cure: 3-5 days mandatory

Dry Film / Coat: 2 mils
VOC: Zero
Flash Point: >350°F

pH: Activator = N/A   Polyol = 9.5 mixed
Mixing Ratio: 50% = 2:1 by weight

Chemical Resistance

Ammonium Hydroxide, Xylene, Skydrol 500 A&B, Acetone, Cellosolve Acetate, Isopropyl Alcohol, Potassium Hydroxide, Perchloroethylene, Methyl Alcohol, Hyjet #3, Urine, Blood, Butyl Cellosolve, Ethy Alcohol, Phosphoric Acid 35%, Sodium Chloride, MEK, Toluene

Specific Gravity: 1.05

Weathering: Excellent

Gloss Retention: Excellent

Appearance and Gloss: ASTM D523

Gloss: 95 @ 60 degree angle

Satin: 25 @ 60 degree angle

Salt Spray: ASTM B117 = 500 hrs

Direct to metal: 1500 hrs. over primer Field (Blister): 10 / Scribe: 7-10

Humidity: ASTM D2244 = 1500 hrs +

Abrasion: ASTM D4060 (taber) < 40mg

Hardness: ASTM D3363 = H to 2H

Adhesion: ASTM D2197 = > 6kg

ASTM D3359 = 5A

Flexibility: ASTM D4195 = Pass

Immersion: ASTM D1308

Elongation: ASTM D522 = >30%

Impact Resistance: ASTM D2794 Direct/Reverse = >160 in. lbs

Solvent Resistance: ASTM D4752

No mar 300 MEK double rubs

Surface Flammability: ASTM E162-02e 1.47 Average Radiant Panel Index

Water Vapor Transmission: ASTM E96-93 = grains/hr-sqft - .028 permeability - .076

Contact Information

For current information, job specs, warranties, or other questions, contact Genesis Coatings, Inc. at (800) 533-4273.

Green Technology

Meets LEED requirements set forth in EQ Credit 4.2

Approved in MPI Categories 105 & 205 for anti-graffiti

Listed on the SCAQMD Super Compliant VOC Paint List

Field tested and approved by the City of Los Angeles

Share by: